OWNER’S MANUAL
FOR
DIRECTORR® DIRECT-DRIVE VACUUM PUMP
MODELS:
8905
8907
8912
8917
8920
8925
Gardner Denver Welch Vacuum Technology, Inc.
5621 W. Howard Street
Niles, IL 60714
Phone: (847) 676-8800
Fax: (847) 677-8606 (Technical Support)
E-Mail: [email protected] Part No. 67-1483R2.5
Web-Page: www.welchvacuum.com Printed in USA
For outside of U.S. and Canada, contact your local
Gardner Denver sales office, see back page
WARNING
Do not block the exhaust port. Pressure will build up with the
potential of oil case bursting with possible injury to personnel.
WARNING
Pumps being run continuously above 1 torr should use an
exhaust oil recycler.
WARNING
Pumps not recommended for filtration, aspiration or drying
electrophoresis gels.
Vue de la page 0
1 2 3 4 5 6 ... 45 46

Résumé du contenu

Page 1

OWNER’S MANUALFORDIRECTORR® DIRECT-DRIVE VACUUM PUMPMODELS:890589078912891789208925Gardner Denver Welch Vacuum Technology, Inc.5621 W. Howard StreetNi

Page 2

102.06 Intake Antisuckback Protection When power to the pump is turned off, this device closes automatically, maintaining vacuum in the system bei

Page 3 - TABLE OF CONTENTS

112.10 UNIBARBTM Intake Fitting - Simplies Small Hose Connections The Unibarb intake tting allows the user to be able to use either 7/16” or 13/1

Page 4

12Section 3: PUMP SPECIFICATIONS3.01 Specication Chart* Partial measurement based upon the American Vacuum Society Test Procedure No. AVS 5.1-1963

Page 5 - Section 1: INSTALLATION

13* Partial measurement based upon the American Vacuum Society Test Procedure No. AVS 5.1-1963 using a trapped McLeod Gauge. SPECIFICATION 8907 89

Page 6

14Section 4: MOTOR SPECIFICATIONS, POWER / FEATURES4.01 Motor Specication ChartCat. No.Voltage Freq. Ph. H.P. Factory Wired forSpecial FeatureAppro

Page 7

154.02 Changing the Voltage Setting on 8907, 8912 and 8917 “A”- Models only The pumps are set for low voltage (LV) 115 volts 60 Hz. They may also

Page 8

164.04 Changing the Voltage Setting on 8905, 8920 and 8925 “A”- Models only The vacuum pump motor is factory wired to for 115 V for models which ope

Page 9

17Section 5: OPERATION5.01 Starting Procedure Before using the pump for the rst time, it is a good idea to spend a few minutes inspecting the pump

Page 10

18Section 6: MAINTENANCE6.01 Vacuum Problems Inability to attain sufcient vacuum in a system is usually due to leakage, contamination, or unusual

Page 11

196.02 Oil Change The best time to change the oil is when the pump is warm and the oil is less viscous. Before attempting an oil change, the pump

Page 12 - 3.01 Specication Chart

INSTRUCTIONWARNING AND CAUTIONPLEASE READ BEFORE OPERATIONWhile reading your manual, please pay close attention to areas labeled: WARNING AND CAUTION.

Page 13

206.04 Lip Seal / Gasket change Changing the Lip Seal and Gasket for 8905 When the shaft seal in the mounting plate shows signs of excessive oil le

Page 14

21 Changing the Lip Seal and Gasket for 8907, 8912 and 8917 When the shaft seal in the mounting plate shows signs of excessive oil leakage, it shoul

Page 15

22 11. REPLACE THE LIP SEAL HOUSING a) It is recommended that you use 3 lockwashers to secure the LIP SEAL HOUSING. Uniform tightness i

Page 16

23 Changing the Lip Seal and Gasket for 8920 and 8925 When the shaft seal in the mounting plate shows signs of excessive oil leakage, it should be r

Page 17 - Section 5: OPERATION

24Section 7: TROUBLE SHOOTING7.01 Leak Detection Problems The importance of eliminating all leaks in a vacuum system is obvious when it is realized

Page 18 - Section 6: MAINTENANCE

257.02 Trouble Shooting GuideCondition Probable Cause Recommended Corrective Action1. Power off. 1. Check switches and fuses.Pump 2. Coupling damaged

Page 19

26Section 8: REPAIR KITS8.01 Shaft Seal Replacement When the shaft seal in the mounting plate shows signs of excessive oil leakage, it should be re

Page 20

27Section 9: ACCESSORIES9.01 Pump Oil When the shaft seal in the mounting plate shows signs of excessive oil leakage, it should be replaced. Bef

Page 21

28Section 10: DRAWINGS AND SPEED CURVE10.10 Speed Curve

Page 22

2910.20 Dimensional DrawingPump Model A B C D E F G H I J K L M N O P Q R S8905A 14.13 8.70 5.52 4.07 5.73 6.81 3.16 0.54 5.58 1.56 6.76 8.70 0.95 0.

Page 23

TABLE OF CONTENTS SECTION PAGESection 01 - Installation 05 1.01 Unpacking 05 1.02 Pump Mounting

Page 24 - Section 7: TROUBLE SHOOTING

3010.30 Exploded Views and Parts List for 8905AItem # Qty. P/N Note A*) Description1 2 62-1014 Screw, Flat Hd #32x3/82 1 61-2370 Window Holder3 1 61-

Page 25 - 7.02 Trouble Shooting Guide

3110.31 Exploded Views and Parts List for 8907AItem # Qty. P/N Description1 4 62-0325 Screw, Socket Hd. M6x20 Blk.2 1 61-6443 Oil Case Assembly3 1 61

Page 26 - Section 8: REPAIR KITS

3210.32 Exploded Views and Parts List for 8912AItem # Qty. P/N Description1 4 62-0325 Screw, Socket Hd. M6x20 Blk.2 1 61-6443 Oil Case Assembly3 1 61

Page 27 - Section 9: ACCESSORIES

3310.33 Exploded Views and Parts List for 8917AItem # Qty. P/N Description1 4 62-0325 Screw, Socket Hd. M6x20 Blk.2 1 61-6443 Oil Case Assembly3 1 61

Page 28 - 10.10 Speed Curve

3410.34 Exploded Views and Parts List for 8920AITEM QTY P/N A* B* DESCRIPTION ITEM QTY P/N A* B* DESCRIPTION1 2 62-1014SCREW FLAT HD #8-32x3/844 2 41

Page 29 - 10.20 Dimensional Drawing

3510.35 Exploded Views and Parts List for 8925AITEM QTY P/N A* B* DESCRIPTION ITEM QTY P/N A* B* DESCRIPTION1 2 62-1014SCREW FLAT HD #8-32x3/8482 61-

Page 30

3610.40 Exploded Views and Parts List for Pump Module 61-6168

Page 31

3710.41 Exploded Views and Parts List for Pump Module 61-6435

Page 32

10.42 Exploded Views and Parts List for Pump Module 61-635438

Page 33

10.50 Exploded Views and Parts List for Oil Case 61-6443ITEM QTY P/N A* B* DESCRIPTION69 2 62-1014 SCREW COUNTER SINK #8-32 x 3/8"70 1 61-6009

Page 34 - PARTS LIST FOR MODEL 8920

4TABLE OF CONTENTS SECTION PAGESection 06 - Maintenance 18 6.01 Vacuum Problems 18 6.02 Oil Change

Page 35 - PARTS LIST FOR MODEL 8925

Section 11: WARRANTYUNPACKING Inspect the pump carefully. If any damage has occurred, le claim with the carrier immediately. Save the shipping co

Page 36

41Section 12: MSDS SHEET FOR 8995PTHE INFORMATION HEREIN IS GIVEN IN GOOD FAITH, BUT NO WARRANTY, EXPRESS OR IMPLIES, IS MADE.Revision Date: 02/10/04

Page 37

42THE INFORMATION HEREIN IS GIVEN IN GOOD FAITH, BUT NO WARRANTY, EXPRESS OR IMPLIES, IS MADE.Revision Date: 02/10/04 Rev. 4 P/N:

Page 38

43THE INFORMATION HEREIN IS GIVEN IN GOOD FAITH, BUT NO WARRANTY, EXPRESS OR IMPLIES, IS MADE.Revision Date: 02/10/04 Rev. 4 P/N:

Page 39

44THE INFORMATION HEREIN IS GIVEN IN GOOD FAITH, BUT NO WARRANTY, EXPRESS OR IMPLIES, IS MADE.Revision Date: 02/10/04 Rev. 4 P/N:

Page 40 - Section 11: WARRANTY

45NOTES_______________________________________________________________________________________________________________________________________________

Page 41 - MATERIAL SAFETY DATA SHEET

USA, Canada, Latin AmericaGardner Denver Thomas, Inc.,Welch Vacuum Technology5621 W. Howard St.Niles, IL 60714 USAPhone: 847-676-8800Fax: 847-677-8

Page 42

5Section 1: INSTALLATION1.01 Unpacking Carefully remove the pump from the shipping carton. Keep all paperwork and inspection tags for future ref

Page 43 - SECTION 8 - CONTROL MEASURES

61.05 Electric Power For Model 8905 Compare the pump motor rating, printed on a label on the side of the motor and on the serial number tag, to t

Page 44 - SECTION 9 – ENVIROMENTAL DATA

71.06 Vacuum Connections The pump inlet is equipped with a UNIBARBTM 7/16” and 13/16” hose tting. The inlet is located next to the pump handle.

Page 45

8Section 2: PUMP FEATURES AND PRINCIPLES OF OPERATION2.01 General Description All of the Welch Vacuum Pumps are two-stage, rotary-vane, oil sealed

Page 46

92.03 Effects of Continued Pressure Reduction The quantity of gas in the vessel (6) is reduced with each evacuation cycle. The gas remaining in the